Buckling length
The factor for calculation of the effective member length for buckling analysis can be specified in this window. The factor is selected according to the support style of the member. Range of supporting styles and factor values are based on general theories for stability analysis. Arbitrary value of the factor can be specified for the sixth option (figure with question marks). Options "Braced members" and "Unbraced members" refer to the frame structure according to the chapter 5.8.3.2(3) of EN 1992-1-1.
Window "Buckling length"