0

FIN EC

Online nápověda

Stromeček
Nastavení
Program:
Jazyk:

Deflection (SLS)

This part of the beam design shows results of deflection verification (serviceability limit state) along the member length. The verification is performed only for load combinations that are dedicated to the serviceability limit state design. If there isn't any entered load combination for serviceability limit state in the part "Load", the results aren't available. The frame in the bottom part contains these settings for deflection verification:

Common requirements

  • This limit shall be considered for deflection that could impair the appearance and general utility of the structure. The values are based on the table 7.2 of EN 1995-1-1.

User defined requirements

  • User defined limit specified as span-depending value

Deflection

  • User defined limit specified as an absolute value in mm

Limits both for characteristic combinations (used for verification of winst) and for combinations, which are dedicated for calculation of final deflection wnet,fin can be specified in the input frame in the bottom part of the window.

Part "Deflection (SLS)" of beam design