Material characteristics of masonry can be specified in this window. The characteristics can be obtained from manufacturers' catalogues or can be specified according to the requirements of designer. These inputs are necessary for determination of strength properties:
Catalogue | - List of the most common manufacturers of masonry units. Arbitrary properties of masonry units can be selected for group "General".
|
Product | - The production range of selected manufacturer is displayed here. Following properties are filled automatically according to the manufacturer's documentation.
|
Kind | - Material of masonry units can be selected for "General" group in "Catalogue". This setting affects the determination of strength properties.
|
Group | - Group in accordance to the paragraph 3.1.1 of EN 1996-1-1 can be selected for "General" group in "Catalogue". Autoclaved aerated concrete, manufactured stone and dimensioned natural stone units areconsidered to be Group 1. Clay, calcium silicate and aggregate concrete units are sorted into Groups 2-4 in accordance with table 3.1 in EN 1996-1-1.
|
Category | - Category in accordance to the appropriate standard (EN 771-1 až EN 771-6) can be selected for "General" group in "Catalogue".
|
Strength fb | - Value of the normalised mean compressive strength of masonry units. This value can be declared by the manufacturer or can be obtained by converting the compressive strength by using given procedure.
|
Load acts parallel to bed joints | - This setting affects the calculation of characteristic value compressive strength of masonry in accordance with paragraph 3.6.1.2.(3).
|
Perpend joints unfilled | - This setting affects the calculation of characteristic value compressive strength of masonry in accordance with paragraph 3.6.1.2.(5).
|
Masonry with longitudinal joint | - Factor K is reduced by 0,8 for masonry with mortar joint parallel to the face of the wall through all or any part of the length of the wall par. 3.6.1.2.(6)).
|
Strength properties of masonry are calculated according to these inputs. Determination of material properties is described in the chapter "Material characteristics" of theoretical part of the help. The material properties can be also specified manually with the help of setting "Own values". These characteristics can be entered:
fk | - characteristic value compressive strength of masonry
|
fvko | - characteristic value of initial shear strength of masonry, under zero compressive stress
|
fxk1 | - Characteristic value of flexural strength of masonry having the plane of failure parallel to the bed joints
|
fxk2 | - Characteristic value of flexural strength of masonry having the plane of failure perpendicular to the bed joints
|
E | |
γM | |
φM | - Creep coefficient, default values are calculated as an average of the ranges specified in the note for the chapter 3.7.4(2)
|
ρ | - Bulk density, this value is used for calculation of self-weight for load type "Vertically loaded wall/column". Default values are based on production catalogues' of producers
|