Serviceability load states

Verification of serviceability limit state is based on standard EN 1996-1-1, paragraph 7.2(5). Dimension limits of the masonry walls are checked in accordance with Annex F. Verification of the serviceability limit state uses clear height of the wall, not the effective height.

Following dimensions are used for the verification of the serviceability limit state:

t

  • the wall thickness

h

  • the clear height of the wall

l

  • the wall length

Due to validity limits of the Annex F ,the minimal thickness of the wall is

Walls restrained at the bottom

Walls restrained at the bottom should satisfy following formula:

Walls restrained at the top and bottom

Walls restrained at the top and bottom should satisfy following formula:

Walls restrained at the bottom and stiffened on one vertical edge

The maximal values of h/t ratio for walls restrained at the bottom and stiffened on one vertical edge are shown in following graph:

Limiting values of h/t ratio depending on l/t ratio

Walls restrained at the top and bottom and stiffened on one vertical edge

The maximal values of h/t ratio for walls restrained at the top and bottom and stiffened on one vertical edge are shown in following graph:

Limiting values of h/t ratio depending on l/t ratio

Walls restrained at the bottom and stiffened on both vertical edges

The maximal values of h/t ratio for walls restrained at the bottom and stiffened on both vertical edges are shown in following graph:

Limiting values of h/t ratio depending on l/t ratio

Walls restrained at the top and bottom and stiffened on both vertical edges

The maximal values of h/t ratio for walls restrained at the top and bottom and stiffened on both vertical edges are shown in following graph:

Limiting values of h/t ratio depending on l/t ratio