Standard selection
The design standard can be selected in this window. These design standards are available: "EN 1992-1-1" (Design of concrete buildings) and "EN 1992-2" (Design of concrete bridges). Different national annexes can be selected for both design standards. The national annex "Default EC" performs the design according to the fundamental Eurocode without any national annex. The values of certain parameters and partial factors γM both for basic and accidental design situations can be specified for option "User defined".
Values of factors and parameters for all available national annexes are written in the chapter "National annexes".
The minimum reinforcement area may be checked for member type "Slab" if the setting "Minimum reinforcement ratio according to CSN 73 1201 - Chap.8.5.2" is switched on. This verification is described in the chapter "Structural rules" of theoretical help.
Button "Default" contains these two tools:
Adopt default settings |
|
Save settings as default |
|
Partial factors are described in the theoretical part of the help.
Window "Standard selection"