Introduction

Calculate the capacity of steel column - concrete footing connection. The steel column is anchored in the concrete footing. The depth of the anchorage is 600mm and the column is located in the centre of the footing. The values of internal forces acting in the connection are: Nx = 694kN, My = 140kNm Vz = 80kN. The material of the column is steel EN 10025: Fe360 and the footing is made of concrete grade C20/25.

Column:

HE 240B

Footing:

bb= 1600mm, ab= 1600mm, hb= 1000mm

End plate:

bp= 280mm, hp= 280mm, tp= 30mm

Creating new project

New connection to the project can be added by clicking the button "Add" in the main dialogue window. The "Add joint" dialogue window will appear, change the joint name to "Concrete footing 2" and confirm by clicking the button "OK".

Creating new joint

Next, the "Joint types" dialogue window will open automatically, choose the preferred type of joint. In this example, it is the column - footing joint.

Joint types

Continue by clicking the button "Next", the dialogue window with the types of connection will appear. Pick the option, where the column is anchored in the concrete footing.

Column - footing connections

When this input is defined, the software will create new task named "Concrete footing 2" at the left side of the main dialogue window.

Main dialogue window for task "Concrete column 2"

Defining properties of the connection

The connection properties are defined in the control tree under the task "Concrete column 2". Every connection has it's own control tree.

Control tree for the selected task

Load cases

First, create new load case by clicking the button "Add" in the "Loads" section.

Adding new load case to the task

The dialogue window, with name of the new load case will appear. Keep the name "Load 1" and continue.

Name of the new load case

Column load

The column load values are defined in the "Column load" section in the control tree. The "Load values" are Nx = 694kN, My = 140kNm Vz = 80kN.

Defining load values

Column base

In this section, define the values of the concrete footing geometry and material. When the geometry is changed, the graphical preview of the footing will automatically re-generate its dimensions.

Geometry and material of the footing

Column position

Now, insert the anchorage depth of the steel column in the concrete footing, hc = 600mm.

The joint position

Column

Define the cross-section of the column by clicking the button "Edit section" and the dialogue window "Column properties" will appear.

The column and the end plate dimensions

The dialogue window "Column properties" shows the preview of the cross-section. The supported types of steel columns are "welded" or "hot-rolled". The predefined type is "hot-rolled", therefore just click the "Edit" button and the catalogue with the cross-sections will appear.

Cross-section of the column

In the dialogue window "Profile catalogue" pick the profile class "Cross-section HE" and choose the profile "HE 240 B". Continue by clicking the "OK" button.

Column profile catalogue

Results

The overall results can be seen at the right-bottom section of the main dialogue window. It shows the capacity of the connection for the least favourable load case. The overall results show that the moment capacity of the connection is My,Rd= 152,14kNm (utilization 92.02%) and normal force capacity Nx,Rd= 2090,67kN (utilization 33.2%). The detailed results for every load case can be shown by selecting the section "Results" in the control tree.