<cover>

This part contains parameters which affect the calculation of reinforcement cover:

class

  • The structure class, available values are: "s1","s2", "s3", "s4", "s5", "s6". The default value is "s4".

life80

  • The design lifetime exceeds 80 years. Available values: "true", "false", default value is "false"

life100

  • The design lifetime exceeds 100 years. Available values: "true", "false", default value is "false"

slab

  • The setting which defines that the member has slab geometry. Available values: "true", "false", default value is "false"

quality

  • Special quality control. Available values: "true", "false", default value is "false"

abbrasion

  • Abrasion class. Available values: "XM1", "XM2", "XM3", the abrasion is not considered as a default

surface

  • The uneven surface correction, optional, default value is 0

cgama

  • Additive safety element Δcdur,γ, default value is 0

cst

  • Stainless steel Δcdur,st, default value is 0

cadd

  • Additional protection Δcdur,add, default value is 0

cdev

  • Allowance in design for deviation Δcdev, default value is 0

ground

  • The ground type. Available values: "prepared" (concrete cast against prepared ground), "soil" (concrete cast against soil). The concrete cast against ground is not considered as a default.