Calculation of passive force in subsuquent stage

If there is new excavation in front of the pile, the passive force can be automatically calculated according to the formula:

gdzie:

F

-

new passive force after excavation

L

-

the depth of slip surface below the terrain in first stage

le

-

the depth of slip surface below the terrain in subsuquent stage

Fo

-

original passive force before excavation